• No results found

Technical Specification for supply and installation of Hi- Tech Fan pad greenhouse for Tissue Culture Hardening

Page 48 of 104 24. Fan & Pad Green

House

(Tender Fee: Rs.

1,500.00)

Application: Fully automatic Fan pad greenhouse is required for primary hardening of tissue culture raised plants.

Comprehensive rate is to be quoted: _________Rs/Sq.m for following specifications (A & B)

A. Technical Specification for supply and installation of Hi-

Page 49 of 104 Profile

U. V. stabilized Polyethylene film 200 micron thickness, IR blocking, Anti drip/fog, Diffused (Multilayor)/run meter

For fixing cladding

Cellulose Pad

Cross fluted Cellulose cooling pads of 1.5 meter height with 100 mm (4 inch) thickness covering the area properly, PVC uniform water disturbing system with each pad have aluminum frame with fittings with the water pumping system 120-150 lpm minimum

20 m length

Pump with accessories (ISI) marked

2 hp single phase (submersible motor- Crompton or approved equivalent) with a minimum discharge 120-150 lpm to distribute water uniformly over pad with 3 layer white plastic tank of 1000 lit and 1 extra mono block motor 1 hp 120- 150 lpm (Crompton or approved equivalent)

For wetting of pads having length of 20 m

Co-axial fan/

fan pad system (IS marked)

Sufficient cooling pads- 36”

with louvers, 1 HP-single phase ISI standard electric motor containing 6SS blades mounted in aluminum frame having air blowing capacity of 10600cfm (300cmm), followed by aluminum/plastic louvers.

Each fan must have regulators

7 no.

Electrical control panel

It consist of Temperature and Humidity control, Piltz and photoperiodic timer, MCB, Relay, switches, RYB indicator, panel, Volt meter, MS body duly painted etc.

1 no.

Heating system

Special Biotech Heat Convector to maintain required temperature, By electric heat convector system 2.5 KW with independent auto operations.

Complete uniform heat circulation system has been given in this heat, so that the heat can be blown in the complete area.

Electrical connections

Standardized cable of desired load with ISI mark to be used for HAF and general purpose requirement where it is necessary

One no CFL should be fitted inside the buffer room for visibility during dark time Plastic water

tank & RWH mechanism

2000 liter 3 layer white plastic

tank with fittings 3 No.

Page 50 of 104 Side walls

Brick wall of size 0.3 meter thick with 1.0 meter height for cooling pad with both side plaster, brick wall of size 0.25 meter thick, 0.25 meter height for periphery.

Air mixing and exhaust fans

Air mixing fans of suitable size(4 Nos) for uniform distribution and exhaust fans of suitable size(2 Nos) for removal of heat from top .

Civil work

Civil work under the stands path as per requirement for piling and foundation Structure is to be erected on CC pilling, Floor: small pieces rocks in bottom and sand on the top

Climate control Fogging system

Overhead four way fogging system sufficient for 200 sq.m of area with 1 HP mono block electric pump and online water filter (Disc filter), 1000ltr unbreakable 3 layer white Plastic water tank, hanging type fine fogger nozzle to be fixed in LLDPE pipe of diameter 16 mm and other accessories. Auto control sensory mechanism specific for overhead humidity generation fogging system, controller to avoid the water logging condition in the unit (Jain/Netafim or approved equivalent)

28 LPH 4 way fogger (zero drain)

Roof Cooling System

Roof cooling provides an extra possibility to lower the temperature in the greenhouse.

Rooftop sprinklers create a thin film of water on the folio, which will be evaporated by the sun.

This supply lines should be fed by PVC underground sub main lines, which are connected to the underground PVC main line

Miscellaneous

Corrosion free, stainless steel washbasin for chamber with drainage points, water connections with tap. ISI standard materials should be provided.

General Lights and electric points inside greenhouse should be provided for additional machines

Page 51 of 104 FIXTURES AND ACCESSORIES

Part name Specification Description Angle

Bracket ISA 40 X 40 X 3 Full angle

Cleat ISA 40 X 40 X 3 Half angle

Cleat ISA 40 X 40 X 3 Flat Patti

25/5mm 25 MM X 5 MM

Full Clamp 76 ID 40 mm Width & 2.9 mm

thick Galvanized/

Zinc plated Half Clamp 76 ID 40 mm Width & 2.9 mm

thick Galvanized/

Zinc plated Full Clamp 60 ID 40 mm Width & 2.9 mm

thick Galvanized/

Zinc plated Half Clamp 60 ID 40 mm Width & 2.9 mm

thick Galvanized/

Zinc plated Full Clamp 43 ID 40 mm Width & 2.6 mm

thick Galvanized/

Zinc plated Half Clamp 43 ID 40 mm Width & 2.6 mm

thick Galvanized/

Zinc plated T-Fixtures 33 mm OD & 2.6 mm thick Galvanized/

Zinc plated L-Fixtures 33 mm OD & 2.6 mm thick Galvanized/

Zinc plated Curtain

Clamp 42 mm Width Galvanized/

Zinc plated Universal

Joint 20 mm sq. bar

Stud Cover 21 mm OD & 2.0 mm thick Galvanized/

Zinc plated Curtain Pipe

Insert 21 mm OD & 2.0 mm thick Galvanized/

Zinc plated Self-

Trapping Screw

20 mm length Galvanized

Bitumen

Washer 3 mm thick Spring Insert 2.3 mm dia.

Spring Insert

(Platting) 2.3 mm dia.

M 10 X 125 10 mm dia. Galvanized

M 10 x 125 10 mm dia. Galvanized/

Zinc plated M 10 X 100 10 mm dia. Galvanized/

Zinc plated

M 10 X 90 10 mm dia. Galvanized/

Zinc plated

M 10 X 40 10 mm dia. Galvanized/

Zinc plated

M 10 Nuts 10 mm dia. Galvanized/

Zinc plated M 10

washers 10 mm dia. Galvanized/

Zinc plated

M 8 X 200 8 mm dia. Galvanized/

Zinc plated

M 8 X 90 8 mm dia. Galvanized/

Zinc plated

Page 52 of 104

M 8 X 65 8 mm dia. Galvanized/

Zinc plated

M 8 Nuts 8 mm dia. Galvanized/

Zinc plated

M 8 washers 8 mm dia. Galvanized/

Zinc plated

M 6 X 75 6 mm dia. Galvanized/

Zinc plated

M 6 X 20 6 mm dia. Galvanized/

Zinc plated

M 6 Nuts 6 mm dia. Galvanized/

Zinc plated

M 6 washers 6 mm dia. Galvanized/

Zinc plated GI Wire 3

mm trellis

wire 3 mm dia. Galvanized/

Zinc plated GI Wire 4

mm trellis supporting wire

4 mm dia. Galvanized/

Zinc plated Pulley with

clamp

HDPE/ MS 40 mm dia. Galvanized

Rings stainless steel

20 m .

ENTRY ROOM (2 DOOR OF 1.2M X 2M ALUMINUM AND POLY CARBONATE MIX)

Description Specification

Entry room size 4 m x 3 m x 2m with Air Curtain No of doors

02 (inner door may be of frame stitched with 40 mesh insect net of minimum 50 cm (IS 16513:2016) overlapping Door size 1.2 m x 2 m; Door of wire gauge angle

framed Frame of door (ISA four

sides to cover the gap below the door)

Galvanized Half part of door

(Downside) Aluminum sheet

Upper half part of door Poly carbonate sheet 5 mm thick Flooring 50 mm PCC flooring over 75 mm thick

sub base PROFILE

Part

Name Specification Description Profile Aluminum profile

Or GI Profile 200 to 220 gr per running m 300 gr per running m Zigzag

spring insert

High carbon steel wire for repeated action, 2.3 mm dia

GI spring over 2 inch strip of new poly film over the main plastic in profile.

(25% over lapping)

Page 53 of 104 CLADDING

Description Specification Plastic films for